4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter

Model Number : MLF

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Electromagnetic Flow Meter

Pipeline Diameter : DN100

Accuracy : Up to 0.2%

Flange : GB/ANSI/JIS/BS/Others

Pressure Rate : 0.6MPa-4.0MPa

IP Class : IP65

Contact Now

Cement Grout Concrete Magnetic Flow Meter

1. Introduction

The MLF electromagnetic flow meter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water, raw water conductivity of about 100 to 500μs/cm), can also be used to measure acids, alkali, brine, pulp or pulp and other media. However, these media must not contain large amounts of magnetic substances and bubbles.

MLF electromagnetic flow meter is an instrument for measuring liquid flow. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textiles, food, urban management, water plants and other industries flow metering.

2.Working Principle

The principle of the sensor is based on Faraday’s law of electromagnetic induction.

It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis

and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and

produces induced electromagnetic force.Which can be measured by the two electrodes on the

meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)

E=KBDV

E——Induced electromotive force,V;

K——meter constant;

B——Magnetic flux density,T;

D——Internal diameter of measuring pipe,m;

V——Average velocity of pipe section,m/s.

1MLF Series Electromagnetic Flow Meter

Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,

K is meter constant,K=4kB/πD.

Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the

measuring electrodes inspect the electromotive force, and transmit to the converter, the

converter provides excitation current.

E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/

pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,

adjusting can be achieved.

3. Features

MLF electromagnetic flowmeter is explosion-proof design.

Low conductivity measurement function.

There are nine language options to meet the needs of different customers.

It has self-regulation function and self-test.

Different outputs are optional: Hart, RS485, Profibus, 4-20mA, frequency, pulse.

4. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

5. Dimensional Sketches

a. Dimension of Converter

4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter

Divided Type

4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter

Integrated Type

4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter

Battery Powered Type

b. Dimension of Sensor

4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof


Product Tags:

DN100 Magnetic Flow Meter

      

IP65 Magnetic Flow Meter

      

4.0MPa Magnetic Flow Meter

      
 4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter Manufactures

4.0MPa DN100 IP65 Cement Grout Magnetic Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)